1. What is the maximum amplitude of FECG recorded during pregnancy?
100 to 300 mV
300 to 500 mV
500 to 700 mV
700 to 900 mV
2. The foetus heart rate is approximately _______ time/s of normal adult foetal heart rate.
one
two
three
four
3. Which of the following is periodic noise source in the foetal ECG signal from the maternal abdomen?
Amplifier input noise
Maternal Muscle noise
Fluctuations in electrode polarization potential
Maternal ECG
4. What is the magnitude of ECG for a typical adult in the standard lead connection?
1 mV
2 mV
3 mV
4 mV
5. Which of the following technique is used to measure foetal heart rate?
ECG
FECG
PCG
VCG
6. What is the CMRR of Foetal electrocardiogram?
0-150 dB
0- 130 dB
0-120 dB
0-200 dB
7. What is responsible for most of the common-mode interfering signal?
Preamplifier
Notch Filter
Power Line Hum
Band Pass Filter
8. What is present in the processing circuit for signal separation?
Preamplifier
Power Line Hum
Notch Filter
Band Pass Filter
9. The F channel has a _______ ms pulse generator that is triggered by the foetal ECG.
5
10
20
30
10. Foetal ECG signal detected via electrodes placed on mother’s abdomen is complex and requires accertion of maternal signals for obtaining FHR.
True
False
11. AECG technique fails in those rare cases where the amniotic fluid fails to provide adequate electrical coupling from foetus to mother.
True
False
12. What is delay time to establish a missing foetal trigger pulse by substitution logic?
150 ms
200 ms
250 ms
270 ms
13. What is the range of FHR measurement due to substitution logic?
0-200 bpm
40-240 bpm
20-220 bpm
60-260 bpm
14. FHR yields important information about the status of ________
fats
eye
fibrous joint
foetus
15. Foetal Heart sounds are listened by digital stethoscope.
True
False
16. To listen to the foetal heart sounds at intervals of up to every _______ minutes is tradition.
5
10
15
20
17. How is the assessment of the condition of foetus can be made during labour?
activity of sweat glands
baseline value of skin resistance
by foetal heart action
baseline value of breathing
18. Which of the following instrument carries out a continuous and simultaneous recording of the instantaneous foetal heart rate and labour activity?
Electrocardiograph
Cardiotocograph
Electromyograph
Vectorcardiograph
19. Sensitivity of _______ bpm/cm of the recording chart allows adequate reading of the recorded FHR.
5
10
15
20
20. What is the used in Tocodynamometry to sense changes in uterine tension transmitted to abdominal skin surface?
U-Manometer
Barometer
Tocotonometer
Picometer
21. Which of the following is a direct method for measuring foetal heart rate?
Abdominal foetal electrocardiogram
Foetal phonocardiogram
Ultrasound technique
Foetal ECG with scalp electrode
22. Cardiotocographs are designed to measure and record foetal heart rate on an average basis.
True
False
23. What is the accuracy of measurement for the classification of responses?
1-2%
2-3%
3-4%
4-5%
24. Ambulatory monitoring of ECG is called ____________
Event Cardiography
Holter Cardiography
Real-Time Cardiography
Implantable Cardiography
25. Which of the following type of systems are not available for ambulatory ECG monitoring?
Holter monitors
Event Recorders
Time Recorders
Implantable Loop Recorders
26. The current state of Holter technology uses small recorders, which size is about _______
75 x 20 x 90 cm
75 x 95 x 20 cm
75 x 20 x 95 mm
75 x 95 x 20 mm
27. Who provides an excellent review of ambulatory cardiac event recorders?
Handelsman
Benz
Alfonso
Friesen
28. The monitor automatically transmits recorded data transtelephonically to a central monitoring station for subsequent analysis when an arrhythmia is detected by an arrhythmia algorithm.
True
False
29. In the data recording, the normal speed of sub miniature tape recorder is ___________
3 cm/s
2 cm/s
3 mm/s
2 mm/s
30. In data recorders, during replay, the tape is run at ________ to achieve rapid manual or automatic scanning of ambulatory records.
80 times of recording speed
70 times of recording speed
60 times of recording speed
50 times of recording speed
31. Which of the following is not an arrhythmic condition?
Cardiographic beat
Bradycardia
Dropped beat
Ectopic beat
32. Which CPU has an overall system control responsibility?
Control
Acquisition
Control and timing
Acquisition and display
33. Full form of P-FCB is ________
Planar-Functional Circuit Board
Planar-Fashionable Circuit Branch
Planar-Functional Circuit Board
Planar-Fashionable Circuit Board
34. Which is the most important physiological parameter monitored in the intensive care unit?
temperature
heart rate
blood pressure
skin color
35. Which of the following instrument is used for monitoring patients with cardiac problems?
Cardiac Monitor
Central Monitor
Bedside Patient Monitor
Blood Pressure Monitor
36. Which of the following instrument is also known as Cardioscopes?
Central Monitor
Bedside Patient Monitor
Cardiac Monitor
Blood Pressure Monitor
37. Disposable type pregelled electrodes to pick up ____________ signal in cardiac monitor.
EOG
EMG
ECG
PCG
38. What is used for amplification of signal in cardiac monitor?
Piezoelectric device
Transducer
Amplifier
Tape recorder
39. _____________ is used to display ECG which enable direct observation of the ECG waveform.
Amplifier
Transducer
Tape Recorder
Cathode ray tube
40. A cardioscope differ in one important aspects as compared to the conventional instrument.
True
False
41. The slow sweep is an outcome of the low frequency character of ________________ signal.
EMG
EOG
ECG
PCG
42. What is total sweep time for a 13-cm screen?
0 to 0.5 s
0.5 to 2 s
2 to 2.5 s
2.5 to 5 s
43. How many heart beat one can observe in a single sweep period?
1
2
3
4
44. What indicate average heart rate with audible beep?
disposable electrodes
heart rate meter
amplifier
cathode ray tube
45. What is diameter of CRT used in small cardioscopes?
1”
3”
5”
7”
46. An alarm system is used to produce signal in event of abnormalities occurring in heart rate.
True
False
47. What is range of RF signals generated by Electrosurgery machine?
0 to 0.4 MHz
0.4 to 5 MHz
5 to 6.5 MHz
6.5 to 10 MHz
48. Which of the following storage device is used for storing digital information in memory monitors?
Hard disk
Magnetic Tape
RAM
DVD
49. Interruption or interference with normal physiological and developmental processes or structures is called _________
Functional Limitation
Pathophysiology
Societal Limitation
Modality-Specific
50. For rehabilitation engineering perspective a task that is specific to a single sense or movement pattern is called ___________
Functional Limitation
Societal Limitation
Modality-Specific
Pathophysiology