Analytical instruments MCQ Quiz Hub

Analytical Instrumentation MCQ Question Set 4

Choose a topic to test your knowledge and improve your Analytical instruments skills

Which of the following UV absorbance detectors provide a real time spectrum of the component of interest?





✅ Correct Answer: 3

Fluorescence detection is less selective than absorption detection.





✅ Correct Answer: 2

Which of the following detectors depend on Snell’s law at the interface between the cell wall and the flowing liquid to deflect the light beam?





✅ Correct Answer: 3

Refractive index detectors used in liquid chromatography are not based on which of the following processes?





✅ Correct Answer: 4

Which of the following detectors can be used for detection of amino acids in protein hydrolyzates by introducing the reagent dansylchloride in the sample?





✅ Correct Answer: 2

The reference cell is packed with which of the following in the Adsorption detector used in liquid chromatography?





✅ Correct Answer: 1

Which of the following detectors used in liquid chromatography is also called micro-adsorption detector?





✅ Correct Answer: 4

In UV-Visible detectors, the cells are not made of which of the following materials?





✅ Correct Answer: 3

Which of the following is not a feature of refractive index type detectors?





✅ Correct Answer: 3

Which of the following detectors can detect almost any component?





✅ Correct Answer: 2

Chromatography is a physical method that is used to separate and analyse _______





✅ Correct Answer: 2

In chromatography, the stationary phase can be _____supported on a solid.





✅ Correct Answer: 1

Which among the following gases have diamagnetic property (ability to be repelled by magnetic fields)?





✅ Correct Answer: 2

Which of the following gases have paramagnetic property (ability to get attracted to a magnetic field)?





✅ Correct Answer: 1

The force produced during the operation of Paramagnetic oxygen analyzer is proportional to which of the following?





✅ Correct Answer: 4

In Paramagnetic oxygen analyzer, the expression for magnitude of force produced can be expressed as, F = C (K-KO), where K= magnetic susceptibility of surrounding gas and KO= magnetic susceptibility of sphere. C denotes which of the following?





✅ Correct Answer: 3

In Paramagnetic oxygen analyzer, the electrostatic force that is exerted should have which of the following features?





✅ Correct Answer: 4

Which of the following is true about the two charged vanes that produce electric field in Paramagnetic oxygen analyzer?





✅ Correct Answer: 3

In Paramagnetic oxygen analyzer, when no oxygen is present the magnetic force balances torque of the fibre.





✅ Correct Answer: 1

To improve paramagnetic oxygen analyzer, the quartz suspension must be replaced with which of the following?





✅ Correct Answer: 1

In the Beckman instrument, the flow rate recommended when the sample enters through a porous diffusion disc is which of the following?





✅ Correct Answer: 2

In the Beckman instrument, the flow rate recommended when the sample enters directly for rapid response is which of the following?





✅ Correct Answer: 3

Which of the following happens to the magnetic susceptibility of gases when the temperature changes?





✅ Correct Answer: 2

If the oxygen content is not greater than 21%, which of the following gases must be used to set the span point?





✅ Correct Answer: 2

If the oxygen content is greater than 21%, which of the following gases must be used to set the span point?





✅ Correct Answer: 1

Which of the following does not occur in Hartman and Braun oxygen analyzer based on the magnetic wind?





✅ Correct Answer: 4

Which of the following is not a cause of the error that could occur in Hartman and Braun oxygen analyzer based on the magnetic wind?





✅ Correct Answer: 3

Hydrocarbons need to be removed from the sample gas to avoid errors in Hartman and Braun oxygen analyzer.





✅ Correct Answer: 1

Magnetic wind analyzers are also known as which of the following?





✅ Correct Answer: 1

In OXYMAT-M oxygen analyser which of the following is usually used as reference gas?





✅ Correct Answer: 4

Which of the following is used in magnetic wind instruments to determine the amount of oxygen?





✅ Correct Answer: 1

Which of the following concepts are not used in magnetic wind instruments?





✅ Correct Answer: 4

How are the hydrocarbons in the samples removed in magnetic wind instruments?





✅ Correct Answer: 1

Which of the following bridges are used in magnetic wind instruments?





✅ Correct Answer: 1

The extremely high inertia of the thin membrane in the oxygen sensor allows it to rapidly attain equilibrium.





✅ Correct Answer: 2

Nitrogen dioxide can be detected with a paramagnetic analyser.





✅ Correct Answer: 1

Nitrogen oxide cannot be directly analysed using UV and Visible analyzers due to which of the following reasons?





✅ Correct Answer: 4

How is NO converted to NO2 for analysis in UV and Visible analyzers?





✅ Correct Answer: 1

How is NO converted to NO2 for analysis in Chemiluminescent analyser?





✅ Correct Answer: 2

During analysis of NO2 using Chemiluminescent analyser, why is NO2 not made to react with ozone directly?





✅ Correct Answer: 2

The instruments based on chemiluminescence maintain linearity in which of the following ranges?





✅ Correct Answer: 3

How can absorption be enhanced while determining NO concentration using CO laser?





✅ Correct Answer: 2

Which of the following detectors are generally used for detection in NO analysis using CO laser?





✅ Correct Answer: 3

Which of the following analyzers are used to measure trace amounts of nitrogen oxides in the stratosphere?





✅ Correct Answer: 3

A pink coloured dye complex is formed when air containing NO2 is passed in an absorbing solution consisting of __________ and diamine dissolved in the acetic acid medium.





✅ Correct Answer: 4

In Laser Opto-acoustic spectroscopy, the IR beam excites the molecules to higher states. In which of the following ways do the molecules return to the ground state?





✅ Correct Answer: 1

To monitor oxides of nitrogen in stack effluents, the sample containing oxides of nitrogen is passed through a flask containing solution of H2O2 in sulphuric acid. Nitric acid is formed. The nitrate ions then react with phenol-disulphonic acid to produce blue colour.





✅ Correct Answer: 2

Which of the following is not an advantage of electrochemical cells used for analysis of H2S?





✅ Correct Answer: 4

Which of the following methods are mainly used in combustible gas detection equipment?





✅ Correct Answer: 2

Which of the following is not an advantage of solid state sensor used for analysis of H2S?





✅ Correct Answer: 4